1. Valve
2. Gate valve, slide valve
The on-off part (shutter) is driven by the valve stem and moves up and down along the valve seat (sealing surface)
A valve that the on-off (shutter) is driven by the valve stem and moves up and down along the valve seat (sealing surface)
3. Globe valve, stop valve
The on-off type (valve shutter) is driven by the valve stem and moves up and down along the axis of the valve seat (sealing surface).
A valve that the on-off(valve shutter) is driven by the valve stem and moves up and down along the axis of the valve seat (sealing surface).
4. Throttle valve
The valve that changes the cross-sectional area of the passage through the on-off (valve shutter) to adjust the flow and pressure
5. Ball valve
On-off type(balls) valve that rotates around a curve perpendicular to the passage. Such as fully welded ball valves.
6. Butterfly valve
On-Off type(butterfly) valve that rotates around a fixed axis.
7. Diaphragm valve
Open-close type (diaphragm) is driven by the valve stem, which moves up and down along the axis of the valve stem and separates the action mechanism from the medium.
A valve that on-off (diaphragm) is driven by the valve stem, and moves up and down along the axis of the valve stem and separates the action mechanism from the medium.
8. Cock
On-off type (plug) valve that rotates around its axis.
9. Check valve, non-return valve
On-off type (valve clack) uses the force of the medium to automatically prevent the medium from flowing back.
On-off type (clack) valve that automatically prevent the medium from flowing back by using the force of the medium.
10. Safety valve, relief valve
Open-close type (valve clack) ,When the medium pressure in the pipeline or machine equipment exceeds the specified value, it will automatically open and shutterharge; when it is below the specified value, it will automatically close and shutterharge, and it will protect the pipeline or machine.
An on-off type(valve clack)valve that automatically open when the medium pressure in the pipeline or machine equipment exceeds the specified value and automatically shut down when the pressure is below the specified value
11. Steam trap
The valve that automatically drains condensate and prevent steam leakage.
12. Draining Valves
Valves are used for blowdown of boilers, pressure vessels and other equipment.
13. Low pressure valve
Various valves with nominal pressure PN≤1.6MPa.
14. Middle pressure valve
Various valves with nominal pressure PN≥2.0~PN<10.0MPa.
15. High pressure valve
Various valves with nominal pressure PN≥10.0MPa.
16.Super high pressure valve
Various valves with nominal pressure PN≥100.0MPa.
17. High temperature valve
It is used for various valves with medium temperature>450℃.
18. Sub-zero valve
It is used for various valves with medium temperature of -40℃~-100℃.
19. Cryogenic valve
It is used for various valves with medium temperature <-100℃.